Movie Play, Script Writing Community

Movie Play is simple to understand: you can create a page for a movie script and then the internet community can write things to that script.

Start directly: You have an idea for a movie: To create a community page for your movie idea write a "working title" for your script into the search field, then search, a page will tell you that the page you searched does not exist of course, then click create page, read the text that appears. enter your idea and don't forget to save.

Movie Play is script writing on movie scripts where everybody can write something. By submitting an idea you admit that everybody can use it in every form. You are welcome as an author: Click Edit in the top right corner of any script and contribute your ideas. If you want to work more with this site read: How to use Movie Play. Keep copies of what you write also on your computer.

The Page:

Scriptwriting Community, Movie Play Home

All Scripts

How to use Movie Play

How to write a movie script

After saving whatever you wrote you will be asked to type "go" into a text field as a captcha and then save again. You give your ideas completely to the scriptwriters community here. In turn: Every script idea you see on this page is yours to use in any way and also sell the product you make from it.

This site uses cookies to work. With using this site you agree to the use of those cookies.

Difference between revisions of "What Is The IEEE 519 Standard"

From Movie Play
Jump to: navigation, search
m
m
Line 1: Line 1:
<br> Also examine shadows.For example, there's at all times two moneybags beneath the far finish of this bridge, however one (magenta) is invisible. If we now have two in any other case equivalent motors, one with a low Kv and one with a excessive Kv, then we will assume that the typical magnetic field produced by the rotor magnets and the dimensions of the rotor itself (i.e. its radius and length) are the same. The motor with fewer turns of wire can have a decrease induced voltage produced by the rotor magnets as they go by the tooth, giving it its high Kv ranking when in comparison with the motor with more turns. You possibly can simply as simply achieve the next torque output by buying a new motor controller with a higher present restrict and retaining your current motor unchanged. The issues begin when you employ a motor controller that outputs a current waveform which doesn't precisely match the bEMF of your motor.<br> <br>This post was generated by GSA Content Generator DEMO.<br><br><br> The particular torque density of an electric motor (torque per unit volume) is independent of its Kv. A sinusoidal bEMF usually means a motor has been wound with distributed windings, the place the windings are distributed over many slots, and is extra common for giant electric motors. The torque functionality of a BLDC motor is set by the typical magnetic subject energy produced by the stator which acts on the rotor, the common magnetic discipline power produced by the rotor magnets which act on the stator and the dimensions of the rotor itself. 3. Reduce the flux gap distance between the rotor and the stator. 2. Replace the everlasting magnets in the rotor with higher power density magnets. However, this assumption fails to take into consideration that the whole area of the copper windings is mounted and therefore the current density remains the same. Therefore, the one potential difference between our two motors can come from the common present density in the stator windings. This data was generated with [https://gsa-online.de/ GSA Content Generator Demoversion]!<br><br><br> This leaves only the common magnetic discipline energy produced by the stator as a potential difference. Let's look at only a single stator tooth and the impact that a unique turn quantity could have on the utilized magnetic field strength when positioned within the out there winding area. The low Kv motor has 10 turns of wire each at 4 A, for a similar total of 40A/tooth. Therefore these two motors will present the identical magnetic subject power and have the identical torque output. Similarly, [https://youlike222.com/%e0%b9%80%e0%b8%84%e0%b8%a3%e0%b8%94%e0%b8%b4%e0%b8%95%e0%b8%9f%e0%b8%a3%e0%b8%b5-youlike222/ เครดิตฟรี] the heat generated by an electric motor while producing a given torque value can also be unbiased of Kv. Useful torque is produced by an electric motor whenever yo[https://www.diagnostiekvooru.nl/locaties-openingstijden/wijkcentrum-t-slot-kastelenplein u] feed in a present waveform to each section that perfectly opposes the a generated bEMF. However, that is basically no completely different than rising the current within the low Kv motor with the same finish result. Once you sum up the current contributions from each section for the sinusoidal waveform (PMSM) and for the trapezoidal waveform (BLDC) you see the same end result; an ideal constant output present, and subsequently a continuing output torque.<br><br><br> Most low-value passion grade motor controllers (ESC's) solely output a 'six-step 120 diploma' present waveform like that proven for the BLDC motor above. Which means that the present waveform produced by an ESC won't ever perfectly match the bEMF of a BLDC motor. For example, consider the torque produced by a PMSM and BLDC motor as seen by the determine under which have been taken from James Mavey's wonderful masters thesis. Therefore, rewinding a motor to extend its Kv solely is smart whenever you wish to match the motor present draw to the current limit of your existing motor controller (ESC). As the facility dissipation within the motor scales with the sq. of the stator current, it feels only pure to assume that the low Kv motor, with its 4A current draw, will produce less heat than our high Kv motor with its 10A present draw. Yes, you could possibly increase the current within the low Kv motor to be the identical because the excessive Kv motor at 10A and produce more torque. However, for high-efficiency purposes (e.g. multi-rotors used for cinematography, robotics and EV purposes) the decreased noise, vibration and increased efficiency that comes from utilizing a FOC motor controller with a PMSM might mean it is worth the additional funding.<br>
+
<br> Also check shadows.For example, there's at all times two moneybags beneath the far end of this bridge, however one (magenta) is invisible. If we've two otherwise similar motors, one with a low Kv and one with a high Kv, then we are able to assume that the typical magnetic subject produced by the rotor magnets and [https://Youlike222.com/%e0%b9%80%e0%b8%84%e0%b8%a3%e0%b8%94%e0%b8%b4%e0%b8%95%e0%b8%9f%e0%b8%a3%e0%b8%b5-youlike222/ เครดิตฟรี] the dimensions of the rotor itself (i.e. its radius and size) are the identical. The motor with fewer turns of wire can have a lower induced voltage produced by the rotor magnets as they pass by the tooth, giving it its high Kv rating when compared to the motor with more turns. You possibly can just as easily achieve the next torque output by buying a brand new motor controller with a higher current limit and keeping your present motor unchanged. The problems start when you use a motor controller that outputs a present waveform which does not exactly match the bEMF of your motor.<br> <br>This post was generated by GSA Content Generator DEMO.<br><br><br> The precise torque density of an electric motor (torque per unit quantity) is impartial of its Kv. A sinusoidal bEMF sometimes means a motor has been wound with distributed windings, the place the windings are distributed over many slots, and is more common for large electric motors. The torque functionality of a BLDC motor is determined by the common magnetic area strength produced by the stator which acts on the rotor, the average magnetic area energy produced by the rotor magnets which act on the stator and the dimensions of the rotor itself. 3. Reduce the flux gap distance between the rotor and the stator. 2. Replace the everlasting magnets within the rotor with larger power density magnets. However, this assumption fails to take into consideration that the full space of the copper windings is fixed and subsequently the present density remains the identical. Therefore, the only doable distinction between our two motors can come from the average current density in the stator windings. This data was generated with [https://gsa-online.de/ GSA Content Generator Demoversion]!<br><br><br> This leaves only the average magnetic discipline strength produced by the stator as a possible difference. Let's look at only a single stator tooth and the impression that a different turn number will have on the applied magnetic subject power when positioned within the accessible winding space. The low Kv motor has 10 turns of wire every at 4 A, for the same total of 40A/tooth. Therefore these two motors will present the same magnetic discipline energy and have the same torque output. Similarly, the heat generated by an electric motor while producing a given torque worth can be impartial of Kv. Useful torque is produced by an electric motor whenever yo[https://www.diagnostiekvooru.nl/locaties-openingstijden/wijkcentrum-t-slot-kastelenplein u] feed in a present waveform to each part that completely opposes the a generated bEMF. However, this is essentially no completely different than growing the current in the low Kv motor with the identical finish consequence. If you sum up the current contributions from every section for the sinusoidal waveform (PMSM) and for the trapezoidal waveform (BLDC) you see the same outcome; a perfect constant output current, and due to this fact a relentless output torque.<br><br><br> Most low-cost interest grade motor controllers (ESC's) only output a 'six-step a hundred and twenty diploma' present waveform like that proven for the BLDC motor above. Which means the present waveform produced by an ESC will never perfectly match the bEMF of a BLDC motor. For example, consider the torque produced by a PMSM and BLDC motor as seen by the determine under which had been taken from James Mavey's glorious masters thesis. Therefore, rewinding a motor to extend its Kv solely makes sense when you want to match the motor present draw to the present limit of your existing motor controller (ESC). As the power dissipation within the motor scales with the sq. of the stator present, it feels only pure to assume that the low Kv motor, with its 4A present draw, will produce less heat than our excessive Kv motor with its 10A present draw. Yes, you might improve the present in the low Kv motor to be the same because the excessive Kv motor at 10A and produce extra torque. However, for top-efficiency purposes (e.g. multi-rotors used for cinematography, robotics and EV applications) the lowered noise, vibration and increased efficiency that comes from using a FOC motor controller with a PMSM may imply it is worth the extra investment.<br>

Revision as of 16:43, 2 May 2021


Also check shadows.For example, there's at all times two moneybags beneath the far end of this bridge, however one (magenta) is invisible. If we've two otherwise similar motors, one with a low Kv and one with a high Kv, then we are able to assume that the typical magnetic subject produced by the rotor magnets and เครดิตฟรี the dimensions of the rotor itself (i.e. its radius and size) are the identical. The motor with fewer turns of wire can have a lower induced voltage produced by the rotor magnets as they pass by the tooth, giving it its high Kv rating when compared to the motor with more turns. You possibly can just as easily achieve the next torque output by buying a brand new motor controller with a higher current limit and keeping your present motor unchanged. The problems start when you use a motor controller that outputs a present waveform which does not exactly match the bEMF of your motor.

This post was generated by GSA Content Generator DEMO.


The precise torque density of an electric motor (torque per unit quantity) is impartial of its Kv. A sinusoidal bEMF sometimes means a motor has been wound with distributed windings, the place the windings are distributed over many slots, and is more common for large electric motors. The torque functionality of a BLDC motor is determined by the common magnetic area strength produced by the stator which acts on the rotor, the average magnetic area energy produced by the rotor magnets which act on the stator and the dimensions of the rotor itself. 3. Reduce the flux gap distance between the rotor and the stator. 2. Replace the everlasting magnets within the rotor with larger power density magnets. However, this assumption fails to take into consideration that the full space of the copper windings is fixed and subsequently the present density remains the identical. Therefore, the only doable distinction between our two motors can come from the average current density in the stator windings. This data was generated with GSA Content Generator Demoversion!


This leaves only the average magnetic discipline strength produced by the stator as a possible difference. Let's look at only a single stator tooth and the impression that a different turn number will have on the applied magnetic subject power when positioned within the accessible winding space. The low Kv motor has 10 turns of wire every at 4 A, for the same total of 40A/tooth. Therefore these two motors will present the same magnetic discipline energy and have the same torque output. Similarly, the heat generated by an electric motor while producing a given torque worth can be impartial of Kv. Useful torque is produced by an electric motor whenever you feed in a present waveform to each part that completely opposes the a generated bEMF. However, this is essentially no completely different than growing the current in the low Kv motor with the identical finish consequence. If you sum up the current contributions from every section for the sinusoidal waveform (PMSM) and for the trapezoidal waveform (BLDC) you see the same outcome; a perfect constant output current, and due to this fact a relentless output torque.


Most low-cost interest grade motor controllers (ESC's) only output a 'six-step a hundred and twenty diploma' present waveform like that proven for the BLDC motor above. Which means the present waveform produced by an ESC will never perfectly match the bEMF of a BLDC motor. For example, consider the torque produced by a PMSM and BLDC motor as seen by the determine under which had been taken from James Mavey's glorious masters thesis. Therefore, rewinding a motor to extend its Kv solely makes sense when you want to match the motor present draw to the present limit of your existing motor controller (ESC). As the power dissipation within the motor scales with the sq. of the stator present, it feels only pure to assume that the low Kv motor, with its 4A present draw, will produce less heat than our excessive Kv motor with its 10A present draw. Yes, you might improve the present in the low Kv motor to be the same because the excessive Kv motor at 10A and produce extra torque. However, for top-efficiency purposes (e.g. multi-rotors used for cinematography, robotics and EV applications) the lowered noise, vibration and increased efficiency that comes from using a FOC motor controller with a PMSM may imply it is worth the extra investment.